CHANGE REQUEST

Request identity number:

C00035

Applies to:

S00663, S00664, S00665, S00666, S00667, S00668, S00669, S00670, S00671, S00672, S00673, S00674, S00675, S00676, S00677, S00678, S00679, S00680, S00681, S00682, S00683

Type of request:

Editorial

Request status level:

Resolved

Proposal:

Validation of IEC 60617-05-05 after loading into the database.


Reason:

Transfer of information from the printed publication IEC 60617-05 Ed. 2 into the IEC 60617 datbase.

Requested by:



TC3

General comments:


Comments at evaluation:


Comments at validation:

Closing for validation 2000-03-04.

JP(HIKE): Symbol S00666, add S00616 in Applying. (Secretary's note: Added. It is not graphically identical, but the point is that ohmic connections are perpendicular to the semiconductor region.)

JP(HIKE): Symbol S00666, S00627 could be added in Applying, but the name of S00625 is very specific. (Secretary's note: S00627 has been added.)

JP(HIKE): Symbol S00667, add S00616 in Applying. (Secretary's note: Added.)

JP(HIKE): Symbol S00667, S00625 could also be added. (Secretary's note: Added.)

JP(HIKE): Symbol S00671, graphics are missing in the application note A00164. (Secretary's note: Yes, it is. We cannot presently add figures in the application notes, but it is possible to add those figures as attachments to the symbol page, if necessary, even if that is not so good. The text of the note is fairly clear on its own, however, so we will have to live with it for the time being and then see if there are so many occurrences of the problem that we will have to find a better solution to it.)

JP(HIKE): Symbols S00671 and S00672, S00616 would also be added in "Applying." (Secretary's note: Accepted.)

JP(HIKE): Symbol S00673, delete S00679 from Applied in. (Secretarys' note: Accepted.)

JP(HIKE): Symbol S00673, add (very similar look) S00675 in "Applied in," which may lead to a technical question.... Please compare S00673 and S00675!! (Secretary's note: Accepted to add the reference. The differences between symbols with and without substrate connection is too small. Actually symbols S00673, ...674, ...676, ..677 and ..678 ought to have shorter channel connection lines since they are not externally accessible, and they had so in IEC 60617 Ed. 1. This is a drawing error in Ed.2 that has been corrected.)

JP(HIKE): Symbol S00674, add S00676 as Applied in. (Secretary's note: Accepted.)

JP(HIKE): Symbol S00678, add S00679 in Applied in. (Secretary's note: Accepted.)

JP(HIKE): Symbol S00679, add S00678 in Applying. (Secretary's note: Accepted.)

JP(HYAM): Symbol S00679, the Graphic shows P-type channel, but the Name has N-type channel. The Graphic or Name should be corrected. (Secretary's note: The graphics is wrong, but it is not only to turn the arrow, the gates are neither well positioned, compared to Ed.1.)

DK(KATH): The symbol S00666 is Applying S00617. (Secretary's note: See the first comment above.)

DK(KATH): If symbols S00668 - S00670 is Applying S00616 the graphic has to be changed a little. (Secretary's note: See the first comment above.)

DK(KATH): For symbol S00680 add "S00627" in Applying and add "Characters" in Shape class. (Secretary's note: Not added. These characters are merely for explanatory purposes in the symbol definition.)

DK(KATH): For symbol S00681 and S00683 add "S00625" in Applying. (Secretary's note. accepted.)

Voting at validation:

FI(TAVI): Symbols S00663 - S00683: Yes
DE(RESC): Symbols S00663 - S00683: YES
AT(WGAS): Symbols S00663 - S00683: Yes
JP(HIKE): Symbols S00663...S00683: YES with comments
DK(KATH): Symbols S00663 - S00683: Yes with comments.

Requested on:

2000-02-14

Evaluated on:

2001-03-21

Resolved on:

2001-03-21

Withdrawn on:


Evaluation closing on:


Validation closing on: