SYMBOL

Symbol identity number:

S01551

Status:

Standard

Last modified:

04/01/2021 09:26:57 PM

Modifiable:

No


Drawing:



Earlier published in:

.

IEC 60617-12 (ed.3.0) 12-15-02

Description (temporary field):

EN

Vm-output

(see also symbol 12-15-01)

If a Vm-input [Vm-output] stands at its internal 1-state, all inputs and outputs affected by this Vm-input [Vm-output] stand at their internal 1-states.
If a Vm-input [Vm-output] stands at its internal 0-state, all inputs and outputs affected by this Vm-input [Vm-output] stand at their normally defined internal logic states.

m shall be replaced by the relevant identifying number.

NOTE - The note with table I applies.


FR

Sortie Vm

(voir également symbole 12-15-01)

Quand un accès Vm est à l'état interne 1, tous les accès influencés par cet accès ont l'état logique interne 1.
Quand un accès Vm est à l'état interne 0, tous les accès influencés par cet accès ont l'état logique interne résultant de la fonction de l'opérateur.

m doit être remplacé par le numéro d'identification.

NOTE - La note du tableau I est applicable.

Name:

EN

Vm-output


FR

Sortie Vm

Alternative names:

EN



FR


Keywords:

EN

binary logic elements; dependency notation; OR dependency


FR

dépendance OU, notation de dépendance, opérateurs logiques binaires

Form:

EN



FR


Alternative forms:



Applied in:


S01665

Applies:



Application notes:


A00269, A00276, A00278, A00288, A00289

Source references:



Published in:



Entered on:


2003-03-27

Evaluated on:


2003-11-28

Released on:


2004-09-01

Rejected on:



Obsolete from:



Proposed by:


TC3

Replaces:



Replaced by:



Shape class:


Characters

Function class:


- Functional elements or attributes

Application class:


Conceptual elements or qualifiers

Symbol restrictions:

EN



FR


Remarks:

EN

If a Vm-output stands at its internal 1-state, all inputs and outputs affected by this Vm-output stand at their internal 1-states.


If a Vm-output stands at its internal 0-state, all inputs and outputs affected by this Vm-output stand at their normally defined internal logic states.


m shall be replaced by the relevant identifying number.


The note with table I of A00276 applies.



FR

Quand un accès Vm est à l'état interne 1, tous les accès influencés par cet accès ont l'état logique interne 1.


Quand un accès Vm est à l'état interne 0, tous les accès influencés par cet accès ont l'état logique interne résultant de la fonction de l'opérateur.


m doit être remplacé par le numéro d'identification.


La note du tableau I de A00276 est applicable.


Change requests:


C00110, C00140, C00146, C00155, C00156, C00189, C00190, C00196

File Attachment Icon
G01551.gif
File Attachment Icon
S01551.eps
File Attachment Icon
S01551.dwg