Xm-input
(see also symbol 12-17A-02)
If an Xm-input [Xm-output] stands at its internal 1-state, a transmission path is established to which all ports affected by this input [output] are connected. However, if a port is affected by two or more Xm-inputs and/or Xm-outputs whose identifying numbers are separated by commas, then the port is connected to the transmission paths established by these Xm-inputs [Xm-outputs] only if all these affecting inputs [outputs] stand at their internal 1-states. All ports connected to a transmission path stand at the same analogue signal level or internal logic state unless modified by additional notation, for example dependency notation.
If an Xm-input [Xm-output] stands at its internal 0-state, no transmission paths are established by this input or output.
If an Xm-input [Xm-output] is modified by additional notation to have no effect on the function of the element, there is no transmission path established by that input or output.
m shall be replaced by the relevant identifying number.
NOTE - The note with table I applies. |

| 
FR | 
Entrée Xm
(voir également symbole 12-17A-02)
Quand un accès Xm est à l'état interne 1, une voie de transmission est établie à laquelle tous les accès marqués du même indice m sont connectés. Toutefois, si un accès est influencé par plusieurs accès Xm avec des numéros d'identification séparés par des virgules, alors l'accès est connecté aux voies de transmission établies par ces accès Xm si, et seulement si, tous ces accès influençants sont à leurs états internes 1. Tous les accès connectés à une voie de transmission sont au même niveau analogique de signal ou au même état logique interne, sauf modification par une autre notation, par exemple une notation de dépendance.
Quand un accès Xm est à l'état interne 0, aucune voie de transmission n'est établie par cet accès.
Quand un accès Xm est influencé, dans le sens d'une notation de dépendance, de sorte qu'il ne peut participer à la fonction d'un opérateur, aucune voie de transmission n'est établie par cet accès.
m doit être remplacé par le numéro d'identification.
NOTE - La note du tableau I est applicable. |

Name: | 
EN | 
Xm-input |

| 
FR | 
Entrée Xm |

Alternative names: | 
EN | 
|

| 
FR | 
|

Keywords: | 
EN | 
binary logic elements; dependency notation; TRANSMISSION dependency |

| 
FR | 
dépendance de TRANSMISSION, notation de dépendance, opérateurs logiques binaires |

Form: | 
EN | 
|

| 
FR | 
|

Alternative forms: | 
| 
|

Applied in: | 
| 
S01605, S01604, S01776, S01805, S01606 |

Applies: | 
| 
|

Application notes: | 
| 
A00269, A00276, A00281, A00288, A00289 |

Source references: | 
| 
|

Published in: | 
| 
|

Entered on: | 
| 
2003-11-27 |

Evaluated on: | 
| 
2003-11-28 |

Released on: | 
| 
2004-09-01 |

Rejected on: | 
| 
|

Obsolete from: | 
| 
|

Proposed by: | 
| 
TC3 |

Replaces: | 
| 
|

Replaced by: | 
| 
|

Shape class: | 
| 
Characters |

Function class: | 
| 
- Functional elements or attributes |

Application class: | 
| 
Conceptual elements or qualifiers |

Symbol restrictions: | 
EN | 
|

| 
FR | 
|

Remarks: | 
EN | 
If an Xm-input stands at its internal 1-state, a transmission path is established to which all ports affected by this input are connected.
However, if a port is affected by two or more Xm-inputs and/or Xm-outputs whose identifying numbers are separated by commas, then the port is connected to the transmission paths established by these Xm-inputs only if all these affecting inputs stand at their internal 1-states. All ports connected to a transmission path stand at the same analogue signal level or internal logic state unless modified by additional notation, for example dependency notation.
If an Xm-input stands at its internal 0-state, no transmission paths are established by this input or output.
If an Xm-input is modified by additional notation to have no effect on the function of the element, there is no transmission path established by that input or output.
m shall be replaced by the relevant identifying number.
The note with table I of A00276 applies.
|

| 
FR | 
Quand un accès Xm est à l'état interne 1, une voie de transmission est établie à laquelle tous les accès marqués du même indice m sont connectés. Toutefois, si un accès est influencé par plusieurs accès Xm avec des numéros d'identification séparés par des virgules, alors l'accès est connecté aux voies de transmission établies par ces accès Xm si, et seulement si, tous ces accès influençants sont à leurs états internes 1. Tous les accès connectés à une voie de transmission sont au même niveau analogique de signal ou au même état logique interne, sauf modification par une autre notation, par exemple une notation de dépendance.
Quand un accès Xm est à l'état interne 0, aucune voie de transmission n'est établie par cet accès.
Quand un accès Xm est influencé, dans le sens d'une notation de dépendance, de sorte qu'il ne peut participer à la fonction d'un opérateur, aucune voie de transmission n'est établie par cet accès.
m doit être remplacé par le numéro d'identification.
La note du tableau I de A00276 est applicable.
|