SYMBOL

Symbol identity number:

S01559

Status:

Standard

Last modified:

04/01/2021 09:37:20 PM

Modifiable:

No


Drawing:



Earlier published in:

.

IEC 60617-12 (ed.3.0) 12-18-02

Description (temporary field):

EN

Cm-output

(see also symbol 12-18-01)

If a Cm-input [Cm-output] stands at its internal 1-state, the inputs affected by this Cm-input [Cm-output] have their normally defined effect on the function of the element.
If a Cm-input [Cm-output] stands at its internal 0-state, the inputs affected by this Cm-input [Cm-output] have no effect on the function of the element.

m shall be replaced by the relevant identifying number.

NOTE - The note with table I applies.


FR

Sortie Cm

(voir également symbole 12-18-01)

Quand un accès Cm est à l'état interne 1, les entrées qu'il influence ont l'effet prévu sur le fonctionnement de l'opérateur.
Quand un accès Cm est à l'état interne 0, les entrées qu'il influence n'ont plus d'effet sur le fonctionnement de l'opérateur.

m doit être remplacé par le numéro d'identification.

NOTE - La note du tableau I est applicable.

Name:

EN

Cm-output


FR

Sortie Cm

Alternative names:

EN



FR


Keywords:

EN

binary logic elements; CONTROL dependency; dependency notation


FR

dépendance de COMMANDE, notation de dépendance, opérateurs logiques binaires

Form:

EN



FR


Alternative forms:



Applied in:


S01677, S01676, S01737

Applies:



Application notes:


A00269, A00276, A00282, A00286, A00288, A00289

Source references:



Published in:



Entered on:


2003-11-27

Evaluated on:


2003-11-28

Released on:


2004-09-01

Rejected on:



Obsolete from:



Proposed by:


TC3

Replaces:



Replaced by:



Shape class:


Characters

Function class:


- Functional elements or attributes

Application class:


Conceptual elements or qualifiers

Symbol restrictions:

EN



FR


Remarks:

EN

If a Cm-output stands at its internal 1-state, the inputs affected by this Cm-output have their normally defined effect on the function of the element.


If a Cm-output stands at its internal 0-state, the inputs affected by this Cm-output have no effect on the function of the element.


m shall be replaced by the relevant identifying number.


The note with table I of A00276 applies.



FR

Quand un accès Cm est à l'état interne 1, les entrées qu'il influence ont l'effet prévu sur le fonctionnement de l'opérateur.


Quand un accès Cm est à l'état interne 0, les entrées qu'il influence n'ont plus d'effet sur le fonctionnement de l'opérateur.


m doit être remplacé par le numéro d'identification.


La note du tableau I de A00276 est applicable.


Change requests:


C00110, C00140, C00150, C00153, C00155, C00156, C00189, C00190, C00196

File Attachment Icon
G01559.gif
File Attachment Icon
S01559.eps
File Attachment Icon
S01559.dwg