Drawing: | 
| 
 |

Earlier published in: | 
. | 
IEC 60617-12 (ed.3.0) 12-44-02 |

Description (temporary field): | 
EN | 
Monostable, non-retriggerable (during the output pulse), general symbol
The output changes to its 1-state only when the input changes to its 1-state. The output returns to its 0-state after a period of time that is characteristic of the particular device, regardless of any changes of the input variable during this period.
NOTE - The use of the dynamic input symbol (symbol 12-07-07) at the input is optional (for example of use see symbol 12-45-02). |

| 
FR | 
Monostable non redéclenchable (pendant l'impulsion de sortie), symbole général
Le changement d'état de 0 à 1 de l'entrée amène la sortie à l'état 1. La sortie retourne à l'état 0 au bout d'un temps, caractéristique de l'opérateur considéré, indépendamment de tout changement d'état de l'entrée intervenant pendant cette durée.
NOTE - L'adjonction du symbole d'entrée dynamique (symbole 12-07-07) est facultative (comme exemple d'application, voir le symbole 12-45-02). |

Name: | 
EN | 
Monostable, non-retriggerable (during the output pulse), general symbol |

| 
FR | 
Monostable non redéclenchable (pendant l'impulsion de sortie), symbole général |

Alternative names: | 
EN | 
|

| 
FR | 
|

Keywords: | 
EN | 
binary logic elements; monostable elements |

| 
FR | 
opérateurs logiques binaires, opérateurs monostables |

Form: | 
EN | 
|

| 
FR | 
|

Alternative forms: | 
| 
|

Applied in: | 
| 
S01677 |

Applies: | 
| 
S00132, S01463, S01472 |

Application notes: | 
| 
A00269 |

Source references: | 
| 
|

Published in: | 
| 
|

Entered on: | 
| 
2004-04-26 |

Evaluated on: | 
| 
2004-04-26 |

Released on: | 
| 
2004-09-02 |

Rejected on: | 
| 
|

Obsolete from: | 
| 
|

Proposed by: | 
| 
TC3 |

Replaces: | 
| 
|

Replaced by: | 
| 
|

Shape class: | 
| 
Characters, Depicting shapes, Rectangles |

Function class: | 
| 
K Processing signals or information |

Application class: | 
| 
Circuit diagrams, Function diagrams |

Symbol restrictions: | 
EN | 
|

| 
FR | 
|

Remarks: | 
EN | 
The output changes to its 1-state only when the input changes to its 1-state. The output returns to its 0-state after a period of time that is characteristic of the particular device, regardless of any changes of the input variable during this period.
The use of the dynamic input symbol (symbol S01472) at the input is optional (for example of use see symbol S01677).
|

| 
FR | 
Le changement d'état de 0 à 1 de l'entrée amène la sortie à l'état 1. La sortie retourne à l'état 0 au bout d'un temps, caractéristique de l'opérateur considéré, indépendamment de tout changement d'état de l'entrée intervenant pendant cette durée.
NOTE - L'adjonction du symbole d'entrée dynamique (symbole S01472) est facultative (comme exemple d'application, voir le symbole S01677). |