Drawing: | 
| 
 |

Earlier published in: | 
. | 
IEC 60617-12 (ed.3.0) 12-51-04 |

Description (temporary field): | 
EN | 
Programmable read-only memory (PROM), 512kx8-bit, shown with READ and WRITE function
(e.g. M27C4001)
Simplified form.
NOTES
1 The notes with symbols 12-51-01 and 12-51-02 apply.
2 The simplified form only shows the READ function. |

| 
FR | 
Mémoire programmable à lecture seule (PROM) de 512k mots de 8 bit, avec fonction de lecture et d’écriture
(modèle d’antériorité : M27C4001)
Forme simplifiée.
NOTES
1 Les notes des symboles 12-51-01 et 12-51-02 sont applicables.
2 Dans la forme simplifiée ne figure que la fonction de lecture. |

Name: | 
EN | 
Programmable read-only memory (PROM), 512kx8-bit |

| 
FR | 
Mémoire programmable à lecture seule (PROM) de 512k mots de 8 bit |

Alternative names: | 
EN | 
|

| 
FR | 
|

Keywords: | 
EN | 
binary logic circuits; memories |

| 
FR | 
circuits logiques binaires, mémoires |

Form: | 
EN | 
Simplified form |

| 
FR | 
Forme simplifié |

Alternative forms: | 
| 
S01713 |

Applied in: | 
| 
|

Applies: | 
| 
S01466, S01498, S01503, S01516, S01518, S01565, S01810 |

Application notes: | 
| 
A00269 |

Source references: | 
| 
|

Published in: | 
| 
|

Entered on: | 
| 
2004-05-03 |

Evaluated on: | 
| 
2004-05-03 |

Released on: | 
| 
2004-09-03 |

Rejected on: | 
| 
|

Obsolete from: | 
| 
|

Proposed by: | 
| 
TC3 |

Replaces: | 
| 
|

Replaced by: | 
| 
|

Shape class: | 
| 
Characters |

Function class: | 
| 
C Storing |

Application class: | 
| 
Circuit diagrams, Function diagrams |

Symbol restrictions: | 
EN | 
|

| 
FR | 
|

Remarks: | 
EN | 
The simplified form only shows the READ function.
E.g. M27C4001.
Because no confusion is likely concerning the correspondence between data inputs and data outputs and because each section has only one output, it is not necessary to show the array.
Simplification of the output labeling is achieved by the use of label grouping; see symbol S01518.
The relative order of the individual outputs is identified by the numbers adjacent to the connecting lines grouped by the label grouping. In this simplified form, the square brackets around these numbers have been omitted.
|

| 
FR | 
Dans la forme simplifiée ne figure que la fonction de lecture.
Modèle d’antériorité : M27C4001.
Du fait qu’il ne peut y avoir de confusion entre les données des entrées et celles des sorties, et que chaque sortie correspond à une section, il n’est pas nécessaire de figurer le détail du groupement.
Simplification en utilisant le groupement de marquage; symbole S01518.
L’ordre relatif des sorties individuelles est identifié par des chiffres à côté des connexions regroupées par le groupement de marquage. Dans cette forme simplifiée, les crochets autour des chiffres ont été omis.
|

Change requests: | 
| 
C00122, C00189 |