Drawing: | 
| 
 |

Earlier published in: | 
. | 
IEC 60617-13 (ed.2.0) 13-05-10 |

Description (temporary field): | 
EN | 
Terminal, shown on the left-hand side, to be externally connected to a subsidiary circuit or circuit element
EXT should be replaced by another designation, e.g.,
RX resistance
CX capacitance
RCX resistance and capacitance
XTAL crystal
NOTES
1 This symbol may be shown without the symbol for subsidiary connection (symbol 13-04-05) if no confusion is likely.
2 If an indication of the polarity is necessary, a + or a - may be added as a suffix to the symbol. |

| 
FR | 
Accès, figuré côté gauche, d'un élément de circuit auxiliaire connecté extérieurement
Il convient de remplacer EXT par une autre désignation, par exemple
RX résistance
CX capacité
RCX résistance et capacité
XTAL cristal piézoélectrique
NOTES
1 Ce symbole peut être figuré sans le symbole de connexion auxiliairs (symbole 13-04-05) s'il n'y a pas de confusion possible.
2 Ce symbole peut être suivi d'un + ou -, lorsqu'il faut indiquer une polarité. |

Name: | 
EN | 
Terminal to be externally connected to a subsidiary circuit or circuit element |

| 
FR | 
Accès d'un élément de circuit auxiliaire connecté extérieurement |

Alternative names: | 
EN | 
|

| 
FR | 
|

Keywords: | 
EN | 
analogue circuits; analogue elements; arithmetic circuits; arithmetic elements; binary logic circuits; binary logic elements |

| 
FR | 
opérateurs analogiques, opérateurs arithmétiques, opérateurs logiques binaires |

Form: | 
EN | 
|

| 
FR | 
|

Alternative forms: | 
| 
|

Applied in: | 
| 
|

Applies: | 
| 
S01752 |

Application notes: | 
| 
A00322, A00352 |

Source references: | 
| 
|

Published in: | 
| 
|

Entered on: | 
| 
2003-03-24 |

Evaluated on: | 
| 
2004-05-05 |

Released on: | 
| 
2004-09-13 |

Rejected on: | 
| 
|

Obsolete from: | 
| 
|

Proposed by: | 
| 
TC3 |

Replaces: | 
| 
|

Replaced by: | 
| 
|

Shape class: | 
| 
Characters |

Function class: | 
| 
- Functional elements or attributes |

Application class: | 
| 
Conceptual elements or qualifiers |

Symbol restrictions: | 
EN | 
|

| 
FR | 
|

Remarks: | 
EN | 
Shown on the left-hand side.
EXT should be replaced by another designation, e.g.,
RX resistance
CX capacitance
RCX resistance and capacitance
XTAL crystal
This symbol may be shown without the symbol for subsidiary connection (symbol S01752) if no confusion is likely.
If an indication of the polarity is necessary, a + or a - may be added as a suffix to the symbol.
|

| 
FR | 
Figuré côté gauche.
Il convient de remplacer EXT par une autre désignation, par exemple
RX résistance
CX capacité
RCX résistance et capacité
XTAL cristal piézoélectrique
Ce symbole peut être figuré sans le symbole de connexion auxiliairs (symbole S01752) s'il n'y a pas de confusion possible.
Ce symbole peut être suivi d'un + ou -, lorsqu'il faut indiquer une polarité.
|

Change requests: | 
| 
C00126, C00189 |