Drawing: | 
| 
 |

Earlier published in: | 
. | 
IEC 60617-13 (ed.2.0) 13-05-12 |

Description (temporary field): | 
EN | 
Adjustment terminal, shown on the left-hand side
The A* shall be replaced by ADJ, or only the asterisk shall be replaced by an indication of the property or quantity to be adjusted.
The following indications should be used for the properties or quantities listed:
B bias
CL current limit
f frequency
H hysteresis
m amplification
OFS offset
P power
SR slew rate
SYM symmetry
T temperature
U or V voltage
WF waveform
Z impedance
.. or .. phase |

| 
FR | 
Accès de réglage, figuré côté gauche
A* doit être remplacé par ADJ, ou bien seul l'astérisque doit être remplacé par une indication sur la propriété ou grandeur à ajuster.
Il convient d'utiliser les indications suivantes pour les propriétés et quantités énumérées ci-après:
B polarisation
CL limitation de courant
f fréquence
H hystérésis
m gain
OFS décalage
P puissance
SR pente
SYM symétrie
T température
U ou V tension
WF forme de l'onde
Z impédance
.. ou .. phase |

Name: | 
EN | 
Adjustment terminal |

| 
FR | 
Accès de réglage |

Alternative names: | 
EN | 
|

| 
FR | 
|

Keywords: | 
EN | 
analogue circuits; analogue elements; arithmetic circuits; arithmetic elements; binary logic circuits; binary logic elements |

| 
FR | 
circuits analogiques, circuits arithmétiques, circuits logiques binaires, opérateurs analogiques, opérateurs arithmétiques, opérateurs logiques binaires |

Form: | 
EN | 
|

| 
FR | 
|

Alternative forms: | 
| 
|

Applied in: | 
| 
S01785, S01799, S01783, S01780, S01794, S01784, S01779, S01787, S01788, S01786, S01602 |

Applies: | 
| 
|

Application notes: | 
| 
A00322, A00352 |

Source references: | 
| 
|

Published in: | 
| 
|

Entered on: | 
| 
2003-03-24 |

Evaluated on: | 
| 
2004-05-05 |

Released on: | 
| 
2004-09-13 |

Rejected on: | 
| 
|

Obsolete from: | 
| 
|

Proposed by: | 
| 
TC3 |

Replaces: | 
| 
|

Replaced by: | 
| 
|

Shape class: | 
| 
Characters |

Function class: | 
| 
- Functional elements or attributes |

Application class: | 
| 
Conceptual elements or qualifiers |

Symbol restrictions: | 
EN | 
|

| 
FR | 
|

Remarks: | 
EN | 
Shown on the left-hand side.
The A* shall be replaced by ADJ, or only the asterisk shall be replaced by an indication of the property or quantity to be adjusted.
The following indications should be used for the properties or quantities listed:
B - bias
CL - current limit
f - frequency
H - hysteresis
m - amplification
OFS - offset
P - power
SR - slew rate
SYM - symmetry
T - temperature
U or V - voltage
WF - waveform
Z - impedance
φ or Φ- phase
|

| 
FR | 
Figuré côté gauche.
A* doit être remplacé par ADJ, ou bien seul l'astérisque doit être remplacé par une indication sur la propriété ou grandeur à ajuster.
Il convient d'utiliser les indications suivantes pour les propriétés et quantités énumérées ci-après:
B - polarisation
CL - limitation de courant
f - fréquence
H - hystérésis
m - gain
OFS - décalage
P - puissance
SR - pente
SYM - symétrie
T - température
U ou V - tension
WF - forme de l'onde
Z - impédance
φ ou Φ - phase
|

Change requests: | 
| 
C00126, C00189 |